New Search
My WebLink
|
Help
|
About
|
Sign Out
New Search
Admin Order 58-03-13-F
COE
>
PW
>
Admin
>
Execs
>
Admin Orders
>
Admin Order 58-03-13-F
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2008 3:40:01 PM
Creation date
8/13/2008 1:35:40 PM
Metadata
Fields
Template:
PW_Exec
PW_Division_Exec
Administration
PWA_Project_Area
Admin Orders
PW_Subject
Streetlight Design Standards
Document_Date
8/4/2003
External_View
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
7.6 Required corrective actions shall be completed within 20 days. Failure to <br /> correct deficiencies is a breach of permit authorization and the City may take any or all of the <br /> follow' g actions: (a) issue citations for violations of law, (b) issue a stop work order until <br /> permit ee has corrected the violations or nonperformance, (c) require permittee's surety <br /> perfo the work for which the permit was issued, (d) use City employees or contractors to <br /> compl a the work and charge the costs thereof to permittee's surety or to permittee's <br /> securit deposit held by the City, (d) revoke the permit or, (fj take any other judicial or <br /> ' ' trative action necessary to insure the performance of the work required by the permit. <br /> 8. The wiring shall be sized to provide a maximum voltage drop of 1 % from the utility <br /> service point t the service cabinet, and a maximum voltage drop of 2% from the farthest light from <br /> the service c ' et on each circuit. The applicant shall provide the City with copies of applicant's <br /> voltage drop alculations for all non-residential street lighting design. <br /> 9. When more than one circuit is connected in a conduit run, each load conductor shall <br /> have its own eparate neutral. No "share" neutrals shall be permitted. <br /> 10. Street lighting conduits shall be installed a minimum of 30-inches below finish grade. <br /> j The prunary 1 cation for street light conduit shall be in a joint trench with other utilities or under the <br /> sidewalk are Joint trenching shall be used and street light conduit shall be located outside of the <br /> plant strip ess the applicant shows that no other reasonable alternative is avafiable. If the plant <br /> strip is appro ed for street light conduit, the conduit shall be installed directly adjacent to the sidewalk <br /> edge, or, one foot from the back side of the curb. In no case shall conduit be installed in an area <br /> which may c nflict with the installation of street trees. <br /> 11. Conduit shall be sized to allow no more than 25% fill. No underground conduit shall <br /> be less than 1 1/2 inch diameter. <br /> 12. Maximum wire size for wire between the service cabinet and luminaires shall be No. <br /> 4 AWG. <br /> 13. Minimum wire size for conductors carrying current to luminaires shall be No. 10 <br /> AWG. <br /> 14. The wire size for conductors carrying current to photo-electric control (PEC) shall <br /> ~ be No. 14 A G. <br /> 15. Single street lights fed from a utility power source shall be controlled by PEC. <br /> Multiple str et lights fed from a lighting circuit shall be controlled by a single master PEC that <br /> operates co actors in the service cabinet. <br /> <br /> ~ 16. Where setback sidewalks are required, street light poles shall be placed in the parkway <br /> no less than hirty-six (36) inches from the center of the pale to the curb face. <br /> 17. Where curbside sidewalks are required, street light poles shall be placed adjacent to <br /> Administrat a Order - 6 <br /> C:\TEMPuD3 ao,wpd(0'7/30/03) <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.