New Search
GJN4166 Elcon Contract
COE
>
PW
>
Admin
>
Finance
>
Capital
>
2008
>
GJN4166 Elcon Contract
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2011 11:07:41 AM
Creation date
6/26/2008 1:13:46 PM
Metadata
Fields
Template:
PW_Capital
PW_Document_Type_Capital
Contracts
PW_Active
No
External_View
No
GJN
004166
GL_Project_Number
945225
Identification_Number
2004100563
COE_Contract_Number
2004-00244
Retention_Destruction_Date
7/5/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6. Anew pump control panel will be developed using a new controller (U.S. Filter D-153). Develop <br /> Control panel outline dimension. Specifications will require the contractor to provide as-built <br /> layout, and interconnection wiring diagram with terminal numbers identified. <br /> 7. Develop Vault Power plan, site plan drawings. We understand that electronic files of existing vault <br /> layout plan is not available. Elcon will develop a plan to show the electrical equipment. Pipes will <br /> not be included in the layout. <br /> 8. Space inside the vault is limited. Current empty wall space on the East side will be used for new <br /> motor starters. Wall space currently used for existing control panel will be used for new control <br /> panel. Due to the limited wall space the motor starter may require a custom designed panel. <br /> 9. Following details will be developed -Pump disconnect panel with bolted cable connection and <br /> conduit. <br /> 10. Develop Division 16 specifications. The front end documents and other Divisions will be <br /> provided by City. <br /> 11. 60% and 90% review and coordination meetings will be conducted through telephone <br /> conference calls. <br /> 12. Development of Construction Cost is NOT required. <br /> C. Assistance During Construction <br /> Following services will be provided to the City during bidding and construction, if desired by the <br /> City. Our fee includes these items. However, the service items may be added or deleted at <br /> City's discretion. <br /> 1. Elcon will provide services to assist City with the assistance during bidding by providing <br /> clarifications related to electrical design work. <br /> 2. Elcon will provide clarification and respond to RFI's related to electrical design work. <br /> 3. Elcon will review the electrical shop drawings submitted by the Contractor. <br /> 4. Elcon will make one trip to site for construction observation, if requested by the City. <br /> 5. Contractor will be required to provide amarked-up copy of as-built electrical drawings. Elcon will <br /> review the drawings and will incorporate the changes marked up by the contractor. A hard copy <br /> and an electronic copy of the as-built drawings will be provided to City at the end. <br /> Assumptions: <br /> 1 Electronic copies of site plan, wet well plan and elevation will be developed by the City and <br /> provided to Elcon for use as background. <br /> 2 Elcon will develop Division 16 specifications. City will develop the front end specifications as <br /> required. The Division 16 specifications will be in CSI format and typed in Word. <br /> 3 City will verify the air change compliance to declassify the vault, and other HVAC requirements <br /> for the vault. <br /> 4 City will provide the overall project management. <br /> 5 City will identify existing utilities, if any, near pump station sites, and identify them on the <br /> background drawings. <br /> 6 A Time and Material contract for services will be negotiated and signed and Notice to Proceed <br /> issued before work will begin. <br /> Proposal Division PS.doc Page 2 of 3 <br /> <br /> Y Schedule/Status Y Communications Y Correspondence <br /> <br /> Y Field Data Y Equipment Info. 7 Meeting Notes Y <br /> Y Specifications Y Calculations Y Cost Estimates <br /> <br />