New Search
My WebLink
|
Help
|
About
|
Sign Out
New Search
FY 2005-06 MWMC Budget & CIP
COE
>
PW
>
Admin
>
Execs
>
Executive non-confidential
>
Historical
>
FY 2005-06 MWMC Budget & CIP
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2009 5:00:01 AM
Creation date
8/21/2009 11:29:39 AM
Metadata
Fields
Template:
PW_Exec
PW_Division_Exec
Administration
PWA_Project_Area
Wastewater
PW_Subject
MWMC
Document_Date
6/30/2006
External_View
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
'~i - ~ ' <br /> NINTH AND TENTH SECONDARY CLARIFIERS <br /> ' Facility Process Component <br /> Secondary Treatment <br /> i <br /> $6,964,000 <br /> <br /> ' I Total Cost <br /> ~ PRIOR <br /> j Costs EXPEND- 2005-06* 2006-07 2007-08 2008-09 2009-10 TOTAL <br /> ITU RES <br /> Design & Engineering .1,004,000 1,004,000 <br /> Construction 5 960 000 5,960,000 <br /> TOTAL 0 1 '004 000 5 960 000 0 0 0 6 964 000 <br /> 'i FUNDING SOURCE <br /> Capital Reserve 1,004,000 3,960,000 4,964,000 <br /> SDC Reimbursement Reserve 100,000 100,000 <br /> 1 SDC Improvement Reserve 1,900,000 0 1 900 000 <br /> TOTAL 0 1,004,000 5,960,000 0 0 0 6,964,000 <br /> * Inflated from 2004 by 6.3% to FY05-06 dollars (Engineering News Record factor) and 4% thereafter <br /> PROJECT: Ninth and tenth secondary clarifiers <br /> DESCRIPTION: This project adds two new 130-ft concrete secondary clarifiers. <br /> JUSTIFICATION: The project provides additional secondary treatment and peak flow management capacity. <br /> PROJECT DRIVER: This project expands the wet weather base capacity (maximum month and maximum week <br /> conditions). DEQ requirement that the peak wet weather flow (5-year, 24-hour rain event) <br /> ' be treated by the EIS WPCF by the year 2010; need to increase the sustained secondary <br /> capacity from approximately 100 mgd to 160 mgd. <br /> PROJECT TRIGGER: Wet season flows through secondary treatment exceeding 134 mgd. <br /> is <br /> TYPE OF PROJECT: 100% Capacity <br /> ESTIMATED PROJECT COST $6,300,000 <br /> (FY 2004-05 Dollard: <br /> INFLATED PROJECT COST $6,964,000 <br /> (FY 2005-06 Dollars): <br /> PHASING: Design budgeted for FY 2005/06 <br /> Construction budgeted for FY 2006/07 <br /> Il <br /> Page 72 FY 05-06 BUDGET AND CIP <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.