(REPLACE) .SECTION 80-08 FAILURE TO COMPLETE ON TIME.. Replace the table in section 80-0$ with <br /> <br /> " the following table: <br /> SCHEDULE LIQUIDATED ALLOWED CONSTRUCTION TIME <br /> DAMAGES <br /> South Kilo -Heavy Pads $500/day 28 consecutive Calendar Days starting no . <br /> sooner than June, 2009; The' Engineer will <br /> specify the start date to Contractor at least <br /> two weeks before the start date. <br /> Overlay North End $500/day 5 consecutive Calendar Days starting no <br /> sooner than August, 2009; The Engineer <br /> . will specify the start date to Contractor at <br /> least two weeks before the start date. <br /> Taxilane TNHT1-02 $200/day 14 consecutive Calendar Days starting no. " <br /> sooner than August, 2009. The Engineer <br /> will specify the start date to Contractor at <br /> least two weeks before the start date. <br /> Pavement Marking Varies See Section P-620 <br /> CHANGES TO TECHNICAL SPECIFICATIONS - ' <br /> (ADD) SECTION P-101 SURFACE PREPARATION. Add to section 101-5.1 PAYMENT. "Item Crack <br /> Sealing -per foot' ~ " <br /> {ADD) SECTION P-151 CLEARING AND GRUBBING. Add the attached ITEM P-151 CLEARING <br /> AND GRUBBING to -the technical specifications.' <br /> (ADD) SECTION P=620 RUNWAY AND TAXIWAY PAINTING. Add to the end of section 620-1.1. <br /> "The Owner will not recognize any subcontractor on the work. The Contractor shall at all times <br /> when pavement marking work is in progress be represented at the site of the pavement marking <br /> work in person, by a qualified superintendent, or by other designated, qualified representative who <br /> is duly authorized to receive and execute orders of the Engineer." <br /> CHANGES TO DRAWINGS <br /> (DELETE) SHEET 5 DETAILS & SECTIONS. Delete ELECTRICAL VAULT ADJUSTMENT DETAIL <br /> drawing and note. <br /> '(ADD) .SHEETS DETAILS & SECTIONS. Add the following note to ELECTRICAL VAULT <br /> ADJUSTMENT DETAIL: "l . Contractor shall remove and replace the existing electrical vault lid. <br /> The Engineer will provide to the Contractor engineered drawings of the vault lid. The Contractor <br /> shall fabricate the vault lid which shall be a reinforced concrete.slab approximately 5'6" x 5'6" x <br /> 12" containing approximately 1001bs. of rebar. The vault lid shall have cast into its center an <br /> aircraft rated East Jordan Iron Works Spring Assist Hatch mode18096 or equal. Payment shall be <br /> made under Bid Item Adjust Electrical Vault per each." <br /> (ADD) SHEET 12 DELTA CENTERLINE MODIFCATIONS. Add the following. note to the <br /> TAXIWAY CENTERLINE RETRO-RELFECTIVE MARKER notes: "4. The Contractor shall <br /> " remove and construct eight retro-reflective markers on Taxiways Lima and Juliette, subject to the . <br /> Construction Notes (19) and (20) on this sheet." <br /> (ADD) SHEETS Al .to A10. Add the attached REHAB NORTH RAMP ADDENDUM Sheets Al to' <br /> A10. <br /> Addendum #2 -Job #4598 Page 2 <br /> <br />