00706.41(c) Preparation of Surface -Crack Sealing <br /> (DELETE) Clean and fill cracks 3 mm (1/8 inch) and larger inside the proposed slung seal <br /> area. <br /> (ADD) Clean cracks, joints and saw cuts of organic and loose material. Fill 1/8" -1/2° <br /> cracks, joints and saw cuts with crack sealant. Fill 1/2" and larger cracks, joints, <br /> and saw cuts with slung seal material. <br /> 00706.43 Application Rate . <br /> (ADD) Application rate shall be for a Type IF mix. <br /> 00706.48 Rolling <br /> (DELETE) Entire sub-section. <br /> (ADD) No rolling of the slurry seal shall be performed as part of this project. <br /> 00706.51 Provision for Traffic <br /> (ADD) Contractor shall provide 48-hour notice. to individual residences using Contractor <br /> provided door hangers. The door hangers shall specify the calendar dates and <br /> approximate times of street closures. The calendar dates specified on the door <br /> hangers shall match the dates from the approved schedule. <br /> 00745.80 General <br /> (DELETE) Entire sub-section. <br /> (ADD) The accepted quantity of HMAC for surface repairs will be measured by the tons. <br /> 00745.90 General <br /> (DELETE) Entire sub-section. <br /> (ADD) The accepted quantity of HMAC for surtace repairs will be paid for at the contract <br /> price per ton. Payment wilt be payment.. in full for furnishing and placing the <br /> materials and for furnishing and ail equipment, labor, and incidentals necessary <br /> to complete the work as specified or~directed by the Engineer. <br /> <br /> Special Provisions - Job #4510 Page 4 <br /> <br />