03/05/2004 FRI 17:00 FAX 541 682 6030 CITY EUGENE PVY ENG -~-~~ FPILOISH CONSTRUCTION f~J008/028 <br />", <br />~~,,,. Note 417: Remove description and replace with "CONST 24" CCP AREA DRAIN <br />WITH CAST IRON GRATE AS PER SPECIAL DRAWING (E-70A)' <br />Note 418: Remove description and replace with "CONST FILTER ROCK 1' WIDTH <br />AROUND AREA DRAIN CONC. PAD 6" IN DEPTH (3/4"-0" CR)" <br />SHEET 5: MH #72050 Profile View: Delete "SUMP 426.51'. <br />MH #72047 Profile View: Delete "SUMP 425.78". <br />SHEET 6: Add note "297 CONSTRUCT STACKED WYE SERVICE LINE PER SPECIAL DRAWING <br />E-54' to wastewater service connection at Station 24+20 Left. <br />SHEET 8: Note 130: Remove description and replace with "CONST CONCRETE BARRIER <br />PER SPECIAL SPECIFICATIONS AND PER STD DWG. No. ERD 505 <br />(NARROW BASE), RD 540 <br />SHEET 9: Note 130: Remove description and replace with "CONST CONCRETE BARRIER <br />PER SPECIAL SPECIFICATIONS AND PER STD DWG. No. ERD 505 <br />(NARROW BASE), RD 540 <br />SHEET 10: Note 130: Remove description and replace with "CONST CONCRETE BARRIER <br />PER SPECIAL SPECIFICATIONS AND PER STD DWG. No. ERD 505 <br />{NARROW BASE), RD 540 <br />SHEET L1.7: Irrigation Legend: In the description column under "RAINBIRD 1812-15SST AND <br />EST SERIES" add nozzle type "PRS SERIES" <br />SHEET L1.6: View 'L': Some irrigation heads are missing between Stations 36+00 and <br />37+00. Replace "VIEW 'L'" window with the attached "VIEW 'L'" <br />revision drawing showing the missing irrigation heads. <br />SHEET L2.7: Landscape Legend: 1n the size/spacing/notes column in the tree stock descriptions, <br />remove the note "B&B" and replace with "CONTAINERIZED <br />STOCK" <br />A copy of the Pre-bid minutes and attendance list is also enclosed in this addendum. <br />If you have questions about this addendum or the project, please call Steve Gallup at <br />(541) 682-8460. <br />All bidders shall acknowledge the receipt of and acceptance of this Addendum No. 1 by signing and <br />submitting the signed Addendum with the bid. Bids submitted without this Addendum, or with the <br />Addendum not signed, will be considered informal. <br />r~ ,~ <br />Ma c oening, P.E. <br />City Engineer <br />Receipt acknowledged and conditions agreed <br />this 10 day of MARCH , 2004. <br />~, Bidder: W I LD I N RUCT N CO . <br />gy: <br />Addendum #1-Job #3502 <br />Page 7 <br />DC!'CillCtl T1~AC ~AnD t: A.C[D~A DoiAir Ti~~r ~~en c c.n~n~~ <br />