New Search
My WebLink
|
Help
|
About
|
Sign Out
New Search
GJN4183 CO 9
COE
>
PW
>
Admin
>
Finance
>
Capital
>
2008
>
GJN4183 CO 9
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/16/2008 4:50:30 PM
Creation date
6/25/2008 10:48:12 AM
Metadata
Fields
Template:
PW_Capital
PW_Document_Type_Capital
Contracts
PW_Active
Yes
External_View
No
GJN
004183
GL_Project_Number
945202
Identification_Number
2004100581
COE_Contract_Number
2004-00024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• Page 3 of 7 <br /> R -P 3 0 <br /> R ' <br /> LOCATION Eugene, Oregon AIP PROJECT NO. 3-41-002&33/34 <br /> Jo o. 4183 <br /> O TRA T R it ' h ons i n o. han O r 9 <br /> JUSTIFICATION FOR CHANGE <br /> 2.. Reason(s) for the change(s) (Continue on reverse if <br /> necessary) <br /> 2150 -Safety Improvements to the Electrlcal Building <br /> Add Hotlxnan box at work bench w/back board - To provide hardware required to safely terminate the 5 KV wires <br /> Change waU packs to canopy lights - This will prevent birds from nesting on the lights and creating a nuisance near the electrical building. <br /> Add 4-way switching in regulator room -This will make it possible to turn the room ligl?ts on from each entrance end lighting the room <br /> before entering it. <br /> Add. 4-way switching in control room -This will make it possible to turn the room lights oa from each entrance and lighting the room <br /> before entering it. <br /> Add second disconnect at the transformer -This is required by the local electrical inspector for safety <br /> 2160 -Functional Improvements to the Electrical Building <br /> a phone jack in the regulator room -This will allow personnel to talk to the ATCT on the phone while looking at the regulators. <br /> Add a phone jack at the work bench -This will allow persrnmel to tallc on the phone while working at the workbench <br /> Add a computer receptacle in the contml room - To provide more options for locating computers in the room and prevent long exposed <br /> computer connecting wires. <br /> Add an outside plug on East side of building - This will allow the use of electrical equipment ~ the outside of the building on the east side. <br /> Add water stop brushes to exterior doors (Including new stainless steel door) -This will help prevent precipitation from entering the <br /> electrical building. <br /> Change the ceiling height in Room 102 to 8=10" -This will make the room necessary to install the ~g lights. <br /> Add three 2-inch conduits under the slab on the East side of the electrical building -This will provide a path far fidure electrical wiring to <br /> the electrical building without disturbing the slab. <br /> <br /> Add a junctiar? box on terminate the three 2-inch conduits -This will pmvide a termination point for the three new conduits, as required by <br /> code. <br /> <br /> Add drawers and a rollout section to the workbench -This will make it possible to better organize files and small electrical components and <br /> <br /> provide a mll out section to trnnspoit electrical components to other rooms and outside the building. <br /> 2170 - ][mprovemenb to a:tend the lifespan of the electrical building <br /> ge door # 103D from mild steel to stainless steel - This will increase the lifetime of the door to match the building <br /> 3 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.