Facility: Residence and Converted Garage, 32275 Fox Hollow Road <br /> ADA Evaluation <br /> 9. TOILET ROOMS (Cont.) <br /> Entrance door: <br /> Must provide 32" unobstructed width when open; door width does not comply - <br /> o new wider door must be installed. See Doors, above. <br /> Door . hardware must be push /pull type or lever operated latches. <br /> Door Closer <br /> 5 Ib. maximum effort to open - if a closer is installed it must meet this requirement. <br /> None required. <br /> Unobstructed space: <br /> Existing toilet rooms do not meet this requirement in their present configuration. <br /> Grab Bars: <br /> 32" - 34" high; 36" long at back and 42" long at side of wc; 1.25 to 1.5" diameter, <br /> 1.5" clear of wall. Grab bars are not provided. <br /> Water closet seat height: <br /> Seat heights must be 17" - 19" high. Existing is approximately 16" high. <br /> Urinal height: <br /> None exist; none required. <br /> Toilet paper dispenser: <br /> New dispensers must be more than 19" above floor and within 12" of front of seat <br /> Hp. <br /> Lavatory: <br /> Does not conform in height, knee space, or valve type. <br /> Mirror: <br /> Does not conform. <br /> Bottom of mirror must be 40" or less above floor. If existing is lowered, top would <br /> be too low. <br /> Towel dispenser: <br /> Must be 48" high to bottom if front access, 54" if side access type. <br />