New Search
My WebLink
|
Help
|
About
|
Sign Out
New Search
GJN4586 Knife River 2010-00024
COE
>
PW
>
Admin
>
Finance
>
Capital
>
2010
>
GJN4586 Knife River 2010-00024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2011 11:35:47 AM
Creation date
6/10/2010 11:21:46 AM
Metadata
Fields
Template:
PW_Capital
PW_Document_Type_Capital
Contracts
PW_Active
No
External_View
No
GJN
004586
GL_Project_Number
995384
COE_Contract_Number
2010-00024
Retention_Destruction_Date
8/11/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FINISH <br />FINISH <br />VALVE BOX <br />4010 <br />" PVC LINER <br />~0 <br />CONCRETI <br />LEAVE NO <br />INSIDE PV( <br />EXISTING VALVE BOX CONFIGURATION <br />ASPHALT <br />SURFACE <br />NOTES: <br />1. USE FOR STREET REBUILD WITH ASPHALT OR CONCRETE AND ANYTIME A STREET CUT IS <br />MADE AROUND VALVE TILE. <br />2. IDENTIFY VALVE LOCATION. <br />3, CUT A 3 FT BY 3 FT DIAMOND CUT IN ASPHALT (CORE DRILLING IS NOT ALLOWED) AND <br />THEN REMOVE ALL MATERIAL TO DEPTH OF VALVE BOX. <br />4. INSTALL FOAM BLOCK IN VALVE TILE TO KEEP DEBRIS FROM FALLING INTO VALVE TILE. <br />5. REMOVE EXISTING VALVE BOX AND DISCARD. <br />6. REMOVE FOAM BLOCK. <br />7. IF EXISTING TILE IS 8" PVC, IT MAY BE REUSED. <br />8. IF' EXISTING TILE IS 10" CONCRETE THEN DO ONE OF THE FOLLOWING: <br />A. REMOVE EXISTING 10" CONCRETE TILE AND REPLACE IT WITH 8" PVC PIPE, <br />CENTERED OVER VALVE NUT. <br />B. IF CONCRETE TILE IS CENTERED OVER VALVE NUT, INSTALL A NEW 8" PVC TILE <br />INSIDE EXISTING 10" VALVE TILE. FILL GAP BETWEEN EXISTING 10" PIPE AND <br />NEW 8" PVC PIPE WITH 3/4" MINUS GRAVEL. (WHEN CUTTING FINAL LIFT). <br />9. INSTALL NEW VALVE BOX AND LID TO FINISHED GRADE: <br />10. INSTALL ASPHALT AND CONCRETE TO FILL IN AREA WITHIN DIAMOND CUT ACCORDING TO <br />CITY OF EUGENE SANITARY CLEANOUT STANDARD RD362(A). <br />ASSEMBLY UST <br />DIEM <br />A5SEWSLY NO. <br />QUANTITY <br />OESCRIPTION <br />1 <br />965-2180 <br />3' <br />8" PVC PIPE, ASTM 3034, SDR 35 <br />2 <br />910-4010 <br />1 <br />VALVE BOX <br />INFORMATION SHOWN IS FOR EWEB. USE ONLY AND IS NOT WARRANTED TO BE ACCURATE FOR UNINTENDED PURPOSES. <br />FUNC BY CHK APP SCALE: NIS <br />WATER STANDARDS REV DATE BY CHK APP <br />DES WADE <br />CONSTRUCTION. <br />DWN NLN TYPICAL VALVE BOX RETROFIT <br />~ ] STREET REBUILD/STREET CUT DWGNO REV <br />SPONSOR ~ <br />IJoAvtw <br />WC5-4.1 zoo 0 <br />DATE: 01/25/08 EUGENE WATER & ELECTRIC BOARD..- EUGENE,. OREGON <br />1 /?9fWM d•-i7 PM <br />VALVE BOX RETROFIT <br />
The URL can be used to link to this page
Your browser does not support the video tag.