New Search
My WebLink
|
Help
|
About
|
Sign Out
New Search
GJN4617 4583 4644 Eugene Sand Contract
COE
>
PW
>
Admin
>
Finance
>
Capital
>
2010
>
GJN4617 4583 4644 Eugene Sand Contract
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2011 3:45:31 PM
Creation date
5/18/2010 11:00:12 AM
Metadata
Fields
Template:
PW_Capital
PW_Document_Type_Capital
Contracts
PW_Active
No
External_View
No
GJN
004583
GL_Project_Number
995354
COE_Contract_Number
2010-00020
Retention_Destruction_Date
10/17/2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FINISH GRADE ASPHALT <br />SURFACE <br />FINISH GRAD 'f •r ' { <br />2 <br />EXIST VALVE BOX <br />910-4010 <br />EXIST 10" PVC LINER <br />910-4630 3/4" MINKS <br />EXIST 10" CONCRETE TILE GRAVEL <br />LEAVE NO DEBRIS <br />INSIDE PVC CONDUIT <br />t <br />VALVE VALVE <br />E <br />~1 1 ~ 1r. <br />rr ti [1 <br />maw.yu <br />EXISTING VALVE BOX CONFIGURATION VALVE BOX RETROFIT <br />NOTES: <br />1. USE FOR STREET REBUILD WITH ASPHALT OR CONCRETE AND ANYTIME A STREET' CUT IS <br />MADE AROUND VALVE TILE. <br />2. IDENTIFY VALVE LOCATION. <br />3. CUT A 3 FT BY 3 FT DIAMOND CUT IN ASPHALT (CORE DRILUNG IS NOT ALLOWED) AND <br />THEN. REMOVE ALL MATERIAL TO DEPTH OF VALVE BOX.. <br />4. INSTALL FOAM BLOCK IN VALVE TILE TO KEEP DEBRIS FROM FALLING INTO VALVE TILE. <br />5. REMOVE EXISTING VALVE BOX AND DISCARD. <br />6: REMOVE FOAM BLOCK. <br />7. IF EXISTING TILE IS 8" PVC. IT MAY BE REUSED. <br />8. IF EXISTING TILE IS 10" CONCRETE THEN DO ONE OF THE FOLLOWING, <br />A. REMOVE EXISTING 10" CONCRETE TILE AND REPLACE IT WITH 8" PVC PIPE, <br />CENTERED OVER VALVE NUT. <br />B. IF CONCRETE TILE IS CENTERED OVER VALVE NUT. INSTALL A NEW 8" PVC TILE <br />INSIDE EXISTING 10" VALVE TILE. FILL GAP BETWEEN EXISTING 10" PIPE AND <br />NEW 8" PVC PIPE WITH 3/4" MINUS GRAVEL. (WHEN CUTTING FINAL LFT). <br />9. INSTALL NEW VALVE BOX AND LID TO FINISHED GRADE. <br />10. INSTALL ASPHALT AND CONCRETE TO FILL IN AREA WITHIN DIAMOND CUT ACCORDING TO <br />CITY OF EUGENE SANITARY CLEANOUT STANDARD RD362(A). <br />ASSEMBLY UST <br />INFORMATION SHOWN IS FOR EWEB USE ONLY AND IS NOT WARRANTED TO BE ACCURATE FOR UNINTENDED PURPOSES. <br />FUNC BY JCIIK <br />SCALE: NTS <br />WATER STANDARDS REV DATE BY CHK APP <br />DES WADE <br />CONSTRUCTION <br />DWN NLN TYPICAL VALVE BOX RETROFIT <br />D/STREET CUT DWGNO REV <br />SPONSOR STREET REBUIL <br />WC5-4.1200 0 <br />DATE: 01/25/08 EUGENE WATER $ ELECTRIC BOARD-EUGENE; OREGON <br />ITEM <br />ASS17ABiY N0. <br />QUANTITY. <br />DESCRIPTION <br />1 <br />965-2180 <br />3' <br />8" PVC PIPE, ASTM 3034, SDR 35 <br />2 <br />910-4010 <br />1 <br />VALVE. BOX <br />
The URL can be used to link to this page
Your browser does not support the video tag.