00756.80 Measurement <br /> (Delete) From the second paragraph the work "yard". <br /> (Add) "foot" <br /> (Add) Joint sealing material shall be measured by the linear foot of sealant in place, <br /> - completed, and accepted. <br /> 756.90 Payment <br /> (Add) Payment for joint sealing material shall be made per linear foot. The price shall be full <br /> compensation for furnishing all materials, for all .preparation, delivering, and placing of <br /> these materials, and for all labor, equipment, tools, and incidentals necessary to <br /> complete the item. <br /> 00759.41 Earthwork <br /> (Delete) "Backfill and restore the form area with crushed aggregate, sandy loam, 2" asphalt <br /> concrete on crushed aggregate, concrete of same thickness as walk, or material to <br /> match existing grade as directed." <br /> (Add) "Backfill and restore disturbed areas to match existing surface and depths with crushed <br /> aggregate, asphalt concrete on crushed aggregate to match existing depths but not less <br /> than 2" asphalt concrete on 6" crushed aggregate base, concrete and base rock of same <br /> thickness to match existing but not less than 4" PCC on 1"crushed aggregate base, 6" <br /> of sandy loam and 2" of mulch with seeding or plantings to match existing, or other <br /> material as required to match existing surface; grade as directed.. All work shall meet the <br /> requirements of the appropriate sections as identified in section 00495." <br /> 00867.45 Installation <br /> (Add) All striping and parking legends shall be Type B, white in color. <br /> 01050.49 Removing and Rebuilding Fence - <br /> (Add) Fence footings shall match existing conditions. Replacement materials shall match the <br /> quality and grade of existing fence material. Submit any new replacement materials.for <br /> approval by Project Manager prior to construction. " <br /> 02440.00 Scope <br /> (Add) This item shall consist of providing and installing a resilient and adhesive joint sealing <br /> filler capable of effectively sealing joints and cracks in pavements. <br /> (Add ) <br /> 02440.12 Joint Materials <br /> Joint sealing materials shall meet the requirements of ASTM D 5893 -Standard <br /> Specifications for Cold Applied, Single Component, Chemically Curing Silicone Joint <br /> Sealant for Portland Cement Concrete. <br /> <br /> Special Provisions -Job #4595 -Fire Station 8 Parking Lot Renovation Page 5 <br /> <br />