New Search
My WebLink
|
Help
|
About
|
Sign Out
New Search
GJN4595 Brown 2009-00023
COE
>
PW
>
Admin
>
Finance
>
Capital
>
2009
>
GJN4595 Brown 2009-00023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2011 11:42:12 AM
Creation date
6/23/2009 9:44:13 AM
Metadata
Fields
Template:
PW_Capital
PW_Document_Type_Capital
Contracts
PW_Active
No
External_View
No
GJN
004595
GL_Project_Number
973632
Identification_Number
2009100414
COE_Contract_Number
2009-00023
Retention_Destruction_Date
3/10/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
00470.11 Precast Concrete Manholes and Bases • <br /> (Add) Stormwater Quality Manholes -Furnish and install an Imbrium Systems Stormceptor <br /> System Model STC 450i, or approved equal. <br /> Supplier Contact Information: <br /> Pete Van Tilburg, Area Manager <br /> Rinker Materials /Stormceptor Products <br /> .800 N.E.. Tenney Road, Suite 413 <br /> Vancouver, WA 98685 <br /> tel. 503-572-9894 <br /> fax. 503-296-2023 <br /> pvantilburgt~rinker.com <br /> pvantilburgta'~cemexusa.com <br /> www.rinkerstormceptor.com <br /> 00641.10 General <br /> (Add) Aggregate Base and Shoulders shall be plant mixed. <br /> The aggregate base shall have not more than 6% by weight passing 'the No. 200 sieve <br /> • when tested in accordance with ASTM C117 (wet sieve test). • <br /> Base material over Stormwater lines shall be Class E backfill. Reference Section <br /> 405.14. <br /> 00641.40. Preparation of the Foundation <br /> (Add) :After completing. the excavation to the designated depth, notify Project Manager for <br /> inspection and approval of the subgrade before backfill is placed. The Engineer may <br /> direct extra depth excavation as needed to remove and backfill unstable areas. <br /> 00756.47 Test Strip <br /> (Delete) Entire Section. . <br /> <br /> _ 00756.48(c) .Construction Joints <br /> (Add) ...Install 1"x.12" smooth dowel bars at 12" o.c. at all construction (cold) joints.' <br /> 00756.48(d) Contraction Joints <br /> (Add) All joints shall be minimum depth of 3'h". <br /> 00756.49(b) Textured Finish <br /> (Delete) Second paragraph. <br /> (Add) All texture finish shall be completed with an AstroturF or broom finish. Markings shall be <br /> transverse to the parking area direction of travel and full parking lot width. . <br /> Special Provisions -Job #4595 -Fire Station 8'Parking Lot .Renovation Page 3 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.