New Search
My WebLink
|
Help
|
About
|
Sign Out
New Search
Admin Order 58-02-25-F (2)
COE
>
PW
>
Admin
>
Execs
>
Admin Orders
>
Admin Order 58-02-25-F (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2009 9:27:06 AM
Creation date
6/1/2009 12:16:52 PM
Metadata
Fields
Template:
PW_Exec
PW_Division_Exec
Administration
PWA_Project_Area
Admin Orders
PW_Subject
Admin
Document_Date
3/31/2003
External_View
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1.1 All proposed tentative planned unit development, site review, or subdivision <br />applications on properties with slopes equal to or greater than 5%; and <br />1.2 All proposed development that includes dedication or construction of a public <br />street or alley or the construction of public drainage systems or public wastewater sewers. <br />2. All design and construction recommendations for public improvements must be <br />corisistent with the adopted City of Eugene Public Improvement Designs Standards and APWA <br />Standard Specifications for Public Works Construction and Amendments. <br />3. As provided in EC 9.6710(5), unless exempt, the category of geological and <br />geotechnical analysis required is based on the following. <br />3.1 A Level 1 analysis shall be required on: <br />3.1.1 All development sites with slopes less than 10% that include <br />construction of public improvements; <br />3.1.2 Subdivision, site review, and planned unit development applications <br />for development sites. with slopes greater than or equal to 5% and less than 10%; <br />3.2 A Leve12 analysis shall be required on: <br />3.2.1 All development sites with slopes greater than or equal to 10% that <br />include construction of public improvements; <br />3.2.2 Subdivision, site review, and planned unit development applications <br />for development sites with slopes greater than or equal to 10%; and <br />3.3 A Leve13 analysis shall be required on development sites where the Level l <br />or Leve12 analysis reveals evidence of existing or potential stability problems or where site <br />conditions such as springs or seeps, depth of soil to bedrock, variations in soil types, or a <br />combination of these conditions, in the opinion of the professional, impact the design <br />parameters of the structure. <br />4. Modifications to the accepted geological and geotechnical report(s) made during <br />construction must be reviewed and accepted by the City prior to implementation. <br />R-9.6710-D Exem tp ions. <br />As provided in EC 9.6710(3), the following activities are exempt from the requirements of <br />EC 9.6710 and the provisions of this rule: <br />1. Maintenance, operation, reconstruction of existing streets, driveways, and utility lines, <br />provided soil disturbance is limited to a standard utility trench width or the area beneath street and <br />driveway structures. <br />Z. Emergency actions which must be undertaken immediately or for which there is <br />insufficient time for full compliance when it is necessary to prevent or abate any of the following: <br />2.1 An imminent threat to public health or safety; <br />2.2 An imminent danger to public or private property; or <br />Administrative Order - 12 <br />R:WDMINORD\RULES\03geotech2ao.wpd(03/26/03) <br />
The URL can be used to link to this page