Formulas for Non-Residential Development <br />Non-Assessable System Valuation <br />Value of existing + Value of planned) = Cost. per unit of capacity <br />Build-out capacity (mgd) <br />Per unit of capacity X flow per PFU for development type X .number of PFUs <br />for development = SDC for development <br />Calculations for Non-Residential Development <br />$100,676M + 9,925M <br />_ $2.2572 per gallon per day <br />49.0 mgd <br />$2.2572 X Gallon per PFU (varies by development type) X <br />Number of PFUs =SDC for development <br />1.3.2 Regional (MWMC) Wastewater System Cost of Service <br />General Formulas <br />Existing and increased plant local <br />equity related to average flow <br />= Cost per gallon of average daily flow <br />Average daily design flow <br />Existing and increased plant local <br />equity related to peak flow Peak flow <br />X =Cost per peak daily ', <br />Peak flow ~ Ave. daily design flow capacity per gallon <br />of average daily flow <br />i' <br />City of `Eugene SDC Methodologies Fee Schedule & Formulas,' Page F-4 <br />